header
projects

projects

George Washington University, School of Business

Location:
2201 G Street, NW
Washington, DC

Date:
August 2004

Client:
Whiting-Turner Contracting Co.

Project Type:
New construction

Building Features:
Special parapet conditions

Structural Attachment Considerations:
Cast in place for concrete
Welded for steel framing

Products Supplied and Installed (all roof anchors were tested):
SM-DVT-CGE Davit cages
SM-DVT-BSE-F5 Formed plate davit bases
SM-DVT-SKT Davit sockets
SM-DVT-ARM Davit arms
SM-5-8-10 Roof anchors
SM-4-4-18 Roof anchors
SM-5-8-6 Soffit anchors
DISCONTINUED Curb anchors (replaced with SM-85-4)

Objective:
Design a suspended maintenance system that includes davits to protect the glass parapet wall (see Davits). Other areas were provided with roof anchors to independently tie back both suspension and fall arrest ropes in areas of the building where the parapet could support the load. Curb anchors were installed where concrete curb was available to avoid roof penetrations. Roof anchors were cast into concrete by the concrete contractor after Summit Anchor Co. supplied layout drawings and anchors.

 

 