header
projects

projects

TYSON'S PARK PLACE

Location:
7926 Jones Branch Dr.
McLean, VA

Date:
August 2005

Client:
B.F. Saul Property Co.

Project Type:
Retrofit – Occupied

Building Features:
Inverted roofing system

Structural Attachment Considerations:
Chemical fasteners for concrete
Through bolt fasteners for concrete

Products Supplied, Installed and Tested:
SM-1-10-10 Roof anchors
SM-81-8-8 Wall anchors
SM-81-4-10 Curb anchors
SM-TRA-ADH-7 Chemical anchor fasteners
SM-1-13-10 Roof anchors
SM-PLT-135-58 Bottom plates
SM-TRA Threaded rod assemblies

Objective:
Design and install a suspended maintenance system for this existing building, which did not meet OSHA and ANSI/IWCA I-14.1 requirements for suspended maintenance workers. This code-compliant system includes anchors installed in concrete beams or columns to avoid roof penetrations where possible. Where these beams and columns were not available, roof anchors were installed. To avoid disturbing tenants in tenant occupied areas, roof anchors were mounted with chemical anchor fasteners where possible. Remaining anchors had to be wrapped around concrete joists, which involved working in tenant occupied areas after office hours.